 Thumbwheel Switch
Easy-to-Assemble Thumbwheel Switch Designed Specially for Printed Circuit Boards
The transparent window plate fitted in the readout section protects dial characters from dust and prevents wear by incorrect handling s Plus (+) and minus (-) pushbuttons for positive forward and reverse rotation of each digital wheel s The contact section is of dust-proof construction s Switch units can be assembled simply by fitting the integral hook coupler of each unit into the mating unit, thus eliminating the need of nuts and bolts for assembly
s
A7CN
Ordering Information
s SWITCH UNITS
Part Number Back mounting PC board Light gray case Black case - A7CN-106-1 Front mounting PC board Light gray case Black case A7CN-206 A7CN-206-1
Output Code 06 (binary code)
s ACCESSORIES
Part Number For back mounting type switch assembly Light gray Black - A7CN-1M-1 - A7CN-1Ps -1 s For front mounting type switch assembly Light gray Black A7CN-2M A7CN-2M-1 A7CN-2Ps s A7CN-2Ps -1 s
Accessory End Cap Spacer
Note: 1. When placing your order, please specify the model numbers and quantities of required switch units, end caps, and spacers, respectively. (Note that switch units and accessories are not factory-assembled for shipment.) 2. Switch case, end cap, and spacer are made of polyacetal resin; however, the window plate is made of polycarbonate resin. 3. One of the following alphabetic codes must be filled into the boxed part of the model number to specify a legend to be hot stamped on the required spacer. 4. End caps come as a set -- left and right. Code A B C D E F G Legend Hot stamp not required SEC MIN H g kg mm Code H J K L Q T Legend cm m o C PCS x 10 SEC 0
A7CN
A7CN
Characteristics
Switching capacity Carry current Contact resistance Insulation resistance Dielectric strength Operating force Vibration Shock Ambient temperature Humidity Service life Weight (per unit) Note: Data shown are of initial value. 1 mA to 0.1 A 50 VAC/28 VDC (resistive load) 1 A (max.) 200 m max. 10 M min. (at 250 VDC) between nonconnected terminals 1,000 M min. (at 250 VDC) between each terminal and noncurrent-carrying part 250 VAC, 50/60 Hz for 1 minute between nonconnected terminals 1,000 VAC, 50/60 Hz for 1 minute between each terminal and noncurrent-carrying part 450 g max. 10 to 55 Hz, 1.5 mm double amplitude 490 m/s2 (approx. 50 g) -10o to 65oC -20o to 80oC 45% to 85% RH max. 30,000 operations (steps) min. 20,000 operations (steps) min. Approx. 1.5 g
Operating Storage Mechanical Electrical
Dimensions
Unit: mm (inch)
s SWITCH UNITS
A7CN-206(-1) Panel cutout
No. of units (n) 1 2 3 4 5 6 7 8 9 10
A (nx6 + 8) 14 (0.55) 20 (0.79) 26 (1.02) 32 (1.26) 38 0.8 (1.500.03) 44 0.8 (1.730.03) 50 0.8 (1.970.03) 56 0.8 (2.200.03) 62 0.8 (2.440.03) 68 0.8 (2.680.03)
B (nx6 + 6) 12 (0.47) 18 (0.71) 24 (0.94) 30 (0.18) 36 0.8 (1.420.03) 42 0.8 (1.650.03) 48 0.8 (1.890.03) 54 0.8 (2.130.03) 60 0.8 (2.360.03) 66 0.8 (2.600.03)
D 12.4 (0.49) 18.4 (0.72) 24.4 (0.96) 30.4 (1.20) 36.8 (1.45) 42.8 (1.64) 48.8 (1.92) 54.8 (2.16) 60.8 (2.39) 66.8 (2.63)
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 2. Each model number applies to a single switch unit and does not apply to the switch assembly as shown in the drawings.
2
A7CN
A7CN-106-1
A7CN
Panel cutout
No. of units (n) 1 2 3 4 5 6 7 8 9 10
A (nx6 + 6) 12 (0.47) 18 (0.71) 24 (0.94) 30 (1.18) 36 0.8 (1.420.03) 42 0.8 (1.650.03) 48 0.8 (1.890.03) 54 0.8 (2.130.03) 60 0.8 (2.360.03) 66 0.8 (2.600.03)
B (nx6 + 11) 17 (0.67) 23 (0.91) 29 (1.14) 35 (1.38) 41 (1.61) 47 (1.85) 53 (2.09) 59 (2.32) 65 (2.56) 71 (2.80)
C (nx6 + 16) 22 (0.87) 28 (1.10) 34 (1.34) 40 (1.57) 46 0.8 (1.810.03) 52 0.8 (2.050.03) 58 0.8 (2.280.03) 64 0.8 (2.520.03) 70 0.8 (2.760.03) 76 0.8 (3.000.03)
D 12.4 (0.49) 18.4 (0.72) 24.4 (0.96) 30.4 (1.20) 36.8 (1.45) 42.8 (1.69) 48.8 (1.92) 54.8 (2.16) 60.8 (2.39) 66.8 (2.63)
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 2. Each model number applies to a single switch unit and does not apply to the switch assembly as shown in the drawings.
3
A7CN
UNIT: mm (inch)
A7CN
s END CAPS A7CN-2M-1
[left] [right]
A7CN-1M-1
[left] [right]
Note: End caps are attached to each end of the switch assembly and used to secure the switch assembly to a mounting panel.
s SPACERS
A7CN-2Ps -1 s A7CN-1Ps -1 s
4
A7CN
s TERMINALS
A7CN-106-1, A7CN-206
A7CN
Hints on Correct Use
Refer to HINTS ON CORRECT USE under the Gene ral In formation section.
Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema
Cat. No. GC SW5
4/98
Specifications subject to change without notice.
Printed in the U.S.A. 5


▲Up To Search▲   

 
Price & Availability of A7CN-206-1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X